Cable Tape / Cable Fim-Double Side Aluminum /PET
Item No. |
DA07157 |
DA091509 |
DA092309 |
DA102510 |
DA152515 |
DA095009 |
DA252525 |
|---|---|---|---|---|---|---|---|
Total Thickness((μm) |
35±3 |
39±5 |
47±5 |
51±5 |
61±5 |
75±5 |
80±5 |
Alumimun foil Thickness(μm)(1) |
7 |
9 |
9 |
10 |
15 |
9 |
25 |
Adhesive Glue(μm) (1) |
/
|
||||||
Polyester Foil(μm) |
15 |
15 |
23 |
25 |
25 |
50 |
25 |
Adhesive Glue(μm) (2) |
/ |
||||||
Alumimun foil Thickness (μm)(2) |
7 |
9 |
9 |
10 |
15 |
9 |
25 |
Basal weight (g/㎡) |
65.0±5 |
75.8±7 |
87.0±7 |
95.2±7 |
116.3±10 |
124.8±10 |
176.5±10 |
Tensile Strength (Kgf/m㎡) |
≥7.0 |
≥7.0 |
≥7.6 |
≥7.8 |
≥8.0 |
≥8.0 |
≥8.0 |
Elongation Break of Rate(%) |
≥20 |
≥20 |
≥30 |
≥50 |
≥20 |
≥30 |
≥20 |
Test standard:
Sample width is the actual width, if product width >50mm, the sample width is 15mm, marked distance150mm, tensile speed 200mm/min.
Tensile test calculation=P/A Cutting loading bearing test=P/W Elongation Break rate calculation=(L-L1)/L1
*P=maximal loading bearing of elongation break (Kgf) *A=sample size(thickness x width) =sample width *L=marked distance of elongation break
Product standard width: according requirement, the product width can be 5mm-980mm. Cutting width ≤100mm,
Tolerance :±0.5mm.Cutting width >100mm, tolerance in ±1mm.